| Sign In | Join Free | My spintoband.com |
|
Brand Name : Rexroth
Model Number : PV7-2X/20-20RA01MA0-10-P85 PV7-1X/06-10RA01MA0-10-P50 PV7-2X/20-25RA01MA0-05-P32
Certification : ISO
Place of Origin : Germany
MOQ : 1
Payment Terms : MoneyGram,Western Union,T/T,D/A,D/P,L/C
Supply Ability : 100
Delivery Time : 2 weeks
Packaging Details : wooden box
Operating Temperature : '-20°C to +80°C
Shaft Rotation Direction : Clockwise (CW) / Counterclockwise (CCW), reversible
Noise Level : ≤ 65 dB(A) at rated speed and pressure
Attribute Category : Parameter Details
Displacement Range : 6 – 100 cm³/rev
PV7-2X/20-20RA01MA0-10-P85
PV7-1X/06-10RA01MA0-10-P50
PV7-2X/20-25RA01MA0-05-P32 PV7 series blade pump imported from Germany by Rexroth in stock
| Parameter/Property Category | Direct-Acting (PV7-A) Series | Pilot-Operated (PV7-C/D/N/W) Series | Unit | Remarks |
| Model Range | PV7-1X/06-10RA01MA0-10, PV7-2X/20-25RA01MA0-10 | PV7-1X/14-20RE01MC0-16, PV7-1X/100-118RE07KD0-16 | - | 1X/2X=component series; 06/14/20=frame size |
| Displacement per Revolution | 10–25 | 14–150 | cm³/rev | Displacement varies by specific model suffix |
| Max. Continuous Working Pressure | 100 | 160 | bar | PV7-A: ≤100 bar; PV7-C/D/N/W: ≤160 bar |
| Max. Peak Pressure | 120 | 200 | bar | Short-term (≤5s) overload only |
| Speed Range | 600–2800 | 600–3600 | rpm | Higher speed for smaller displacement models |
| Max. Flow Rate (at 1800 rpm) | 36 | 270 | l/min | Calculated at rated displacement |
| Volumetric Efficiency (Rated Condition) | ≥90% | ≥92% | % | At 160 bar, 1800 rpm, ISO VG 46 oil |
| Total Efficiency (Nominal Operation) | ≥80% | ≥82% | % | Includes mechanical & volumetric efficiency |
| Suction Pressure Range | -0.8 to +1 | -0.8 to +1 | bar | Absolute pressure: 0.2–1.1 bar |
| Fluid Compatibility | Mineral oil (HLP), synthetic oil (HETG/HEES) | Mineral oil (HLP), synthetic oil (HETG/HEES) | - | Use FKM seals for synthetic fluids |
| Fluid Viscosity Range | 10–1000 (operation); 2–1500 (start-up) | 10–1000 (operation); 2–1500 (start-up) | mm²/s | Optimal: 16–160 mm²/s |
| Fluid Temperature Range | -20 to +80 | -20 to +80 | °C | Storage: -40 to +90 °C |
| Noise Level (1 m Distance, Rated Operation) | ≤63 | ≤65 | dB(A) | Pilot-operated models have optimized noise reduction |
| Mounting Standard | ISO 3019-2 flange | ISO 3019-2 flange | - | Optional foot mounting for some models |
| Shaft Connection | ISO 4162 splined shaft | ISO 4162 splined shaft | - | Keyed shaft available on request |
| Seal Material | NBR (standard); FKM (optional) | NBR (standard); FKM (optional) | - | NBR for mineral oil; FKM for synthetic oil |

| PV7-1X/06-14RA01MA0-10-A473 |
| PV7-1X/06-10RA01MA0-10-P100 |
| PV7-1X/06-14RA01MA0-10-A492 |
| PV7-2X/20-20RA01MA0-10-C3.1 |
| PV7-2X/20-20RA01MA0-05-A480 |
| PV7-2X/20-20RA01MA0-10-A480 |
| PV7-1X/06-10RA01MA0-10-C3.1 |
| PV7-2X/20-20RA01MA0-10-P100 |
| PV7-2X/20-25RA01MA0-05-P24Q30 |
| PV7-1X/06-10RA01MA0-05-P35Q11 |
| PV7-2X/20-25RA01MA0-05-P30Q25 |
| PV7-1X/06-10RA01MA0-05-P40Q11 |
| PV7-2X/20-25RA01MA0-05-P30Q36 |
| PV7-1X/06-10RA01MA0-05-P50Q15 |
| PV7-2X/20-25RA01MA0-05-P45Q35 |
| PV7-1X/06-10RA01MA0-10-P55Q12 |
| PV7-2X/20-25RA01MA0-05-P45Q36 |
| PV7-1X/06-10RA01MA0-10-P65Q12 |
| PV7-2X/20-25RA01MA0-10-P63Q35 |
| PV7-1X/06-10RA01MA0-10-P70Q12 |
| PV7-1X/06-10RA01MA0-05-P15Q08 |
| PV7-1X/06-14RA01MA0-07-P70Q18 |
| PV7-1X/06-10RA01MA0-05-P25Q09 |
| PV7-1X/06-14RA01MA0-04-P30Q19 |
| PV7-1X/06-10RA01MA0-05-P25Q11 |
| PV7-1X/06-10RA01MA0-10-P100Q10 |
| PV7-1X/06-10RA01MA0-05-P35Q09 |
| PV7-1X/63-71RE07MC3-16 |
| PV7-1X/100-118RE07MD3-16 |
| PV7-1X/63-71RE07MW0-16WG |
| PV7-1X/10-20RE01MD5-10 |
| PV7-1X/25-30RE01MW0-16WG |
| PV7-1X/40-45RE37MW5-16WG |
| PV7-1X/100-118RE07MC5-16WG |
| PV7-1X/63-94RE07MC7-08WG |
| PV7-1X/40-45RE37MW6-16WH |
| PV7-1X/100-118RE07MD6-16 |
| PV7-1X/40-45RE37MC5-16WG |
| PV7-1X/100-118RE07MC0-16 |
| PV7-1X/63-71RE07MD0-16 |
| PV7-1X/40-45RE37MC0-16-P90 |
| PV7-1X/25-30RE01MC0-16-P100Q38 |
| PV7-1X/100-150RE07MC0-08-A464 |
| PV7-1X/100-118RE07MD0-16 |
| PV7-1X/10-14RE01MN0-16 |
| PV7-1X/40-45RE37MC5-16 |
| PV7-1X/100-118RE07MC5-16 |
| PV7-1X/25-30RE01KC3-16 |
| PV7-1X/10-20RE01MC5-10WG |
| PV7-1X/25-30RE01MW0-16 |
| PV7-1X/16-20RE01MD3-16 |
| PV7-1X/16-20RE01MC0-16-P110 |
| PV7-1X/40-45RE37KD0-16-C3.1 |
| PV7-1X/63-71RE07MC5-16WH |
| PV7-1X/16-30RE01KC0-08 |
| PV7-1X/10-14RE01MD5-16 |
| PV7-1X/63-71RE07MC6-16 |
| PV7-1X/16-20RE01KD0-16 |
| PV7-1X/10-14RE01MW0-16 |
| PV7-1X/63-71RE07MC0-16-C3.1 |
| PV7-1X/16-30RE01MW0-08WH |
| PV7-1X/100-150RE07MC0-08-A446 |
| PV7-1X/25-30RE01MC5-16WG |
| PV7-1X/10-20RE01MC0-10-A497 |
| PV7-1X/100-150RE07KC0-08 |
| PV7-1X/100-150RE07MD5-08 |
| PV7-1X/25-45RE01MC0-08-P25Q50 |
| PV7-1X/40-71RE37MC5-08 |
| PV7-1X/10-14RE01KD0-16 |
| PV7-1X/16-20RE01MC0-16-P120 |
| PV7-1X/100-150RE07MW0-08WH |
| PV7-1X/16-20RE01MC5-16WG |
| PV7-1X/10-20RE01MW0-10WH |
| PV7-1X/63-94RE07KD0-08 |
| PV7-1X/63-71RE07MW0-16WH |
| PV7-1X/63-71RE07MC7-16WH |
| PV7-1X/40-45RE37MC0-16 |
| PV7-1X/63-94RE07MC0-08-P80Q114 |
| PV7-1X/40-45RE37MC5-16WH |
| PV7-1X/10-14RE01KN0-16 |
| PV7-1X/25-30RE01MC5-16WH |
| PV7-1X/63-71RE07KC0-16 |
| PV7-1X/10-20RE01MC3-10 |
| PV7-1X/16-20RE01MN0-16 |
| PV7-1X/25-45RE01MW0-08WH |
| PV7-1X/63-71RE07MN0-16 |
| PV7-1X/63-71RE07KD0-16 |
| PV7-1X/16-20RE01MC8-16 |
| PV7-1X/40-71RE37MW0-08WH |
| PV7-1X/40-45RE37MD0-16-P50Q36 |
| PV7-1X/40-45RE37MC7-16WG |
| PV7-1X/100-118RE07MN5-16 |
| PV7-1X/25-45RE01MC7-08WG |
| PV7-1X/63-71RE07MC7-16 |
| PV7-1X/100-150RE07MC3-08 |
| PV7-1X/40-45RE37KC0-16 |
| PV7-1X/63-94RE07MC5-08 |
| PV7-1X/16-20RE01MC0-16-P60Q26 |
| PV7-1X/16-20RE01MC5-16 |
| PV7-1X/40-71RE37MC5-08WG |
| PV7-1X/25-45RE01MC7-08 |
| PV7-1X/25-30RE01MW5-16WH |
| PV7-1X/10-20RE01MD0-10 |
| PV7-1X/63-71RE07MD0-16-Q90 |
FAQ:
1. What is the recommended clearance around the PV7 pump for installation?
Reserve ≥10cm of heat dissipation space, away from high-temperature heat sources.
2. Should the PV7 pump’s mounting surface be treated before installation?
Yes, remove oil, burrs, and weld slag; use wear-resistant gaskets (≤2mm thick) if flatness is insufficient.
3. What material is recommended for the PV7 pump’s mounting base?
Cast iron or steel plates are preferred for sufficient rigidity to reduce vibration transmission.
4. How to handle the suction and discharge pipes of the PV7 pump?
• Suction pipe: Inner diameter ≥ pump suction port, length ≤2m, ≤2 elbows;
• Discharge pipe: Install independent supports to avoid stress on the pump flange.
5. What thread standards are available for PV7 pump ports?
BSPP, BSPT, or SAE threads (port size matches displacement).
|
|